{ "Name": "Kim2025 – 40-class beta-range SSVEP speller dataset", "BIDSVersion": "1.9.0", "HEDVersion": "8.4.0", "DatasetType": "derivative", "License": "CC BY 4.0", "Authors": [ "Heegyu Kim", "Kyungho Won", "Minkyu Ahn", "Sung Chan Jun" ], "EthicsApprovals": [ "GIST IRB, No. 20211201-HR-64-02-04" ], "ReferencesAndLinks": [ "https://doi.org/10.6084/m9.figshare.28806815.v2" ], "GeneratedBy": [ { "CodeURL": "https://github.com/NeuroTechX/moabb", "Name": "moabb", "Description": "Mother of All BCI Benchmarks", "Version": "1.4.3" } ], "SourceDatasets": [ { "DOI": "10.1038/s41597-025-06032-2", "URL": "https://doi.org/10.6084/m9.figshare.28806815.v2" } ], "Keywords": [ "SSVEP", "BCI", "beta range", "visual fatigue", "40-class speller", "JFPM", "EEG" ], "PublicationYear": 2025, "ExperimentName": "Kim2025", "Description": "40-class beta-range SSVEP speller dataset.\n\n\nDataset summary:\n\n#Subj 40\n#Chan 33\n#Classes 40\n#Trials / class 6\nTrials length 5 s\nFreq 1024 Hz\n#Sessions 6\n\n\nParticipants:\n\n- Population: healthy\n- Age: 22.8 (range: 20-35) years\n- BCI experience: 3 of 40 had prior SSVEP-BCI experience\n\n\nEquipment:\n\n- Amplifier: BioSemi ActiveTwo\n- Electrodes: active\n- Montage: standard_1005\n- Reference: CMS/DRL\n\n\nPreprocessing:\n\n- Data state: epoched\n\n\nData Access:\n\n- DOI: 10.1038/s41597-025-06032-2\n- Data URL: https://doi.org/10.6084/m9.figshare.28806815.v2\n- Repository: Figshare\n\n\nExperimental Protocol:\n\n- Paradigm: ssvep\n- Task type: speller\n- Feedback: none\n- Stimulus: JFPM visual flicker\n\nDataset from [1]_.\n\nThis dataset contains 33-channel EEG (31 scalp + 2 mastoid references)\nrecorded from 40 healthy subjects (25 males, 15 females, aged 20-35)\nperforming a 40-target SSVEP-BCI speller task using beta-range frequencies\n(14.0-21.8 Hz, 0.2 Hz step). The JFPM approach was used with phase\ndifferences of 0.5*pi between adjacent stimuli.\n\nEach subject completed 6 blocks of 40 trials. Trial structure was 1.5 s\nrest, 0.5 s cue, and 5.0 s SSVEP stimulation. EEG was recorded at 1024 Hz\nwith a BioSemi ActiveTwo system. Stored epochs span [-2000, 5000] ms\nrelative to stimulus onset (7168 samples at 1024 Hz). The event marker is\nplaced at stimulus onset (sample 2048), and interval=[0.0, 5.0] extracts\nthe 5 s stimulation window.\n\nThe stimuli were presented in a 5x8 matrix on a 120 Hz monitor.\n\nReferences\n----------\n.. [1] H. Kim, K. Won, M. Ahn, and S. C. Jun, \"A 40-class SSVEP speller\ndataset: beta range stimulation for low-fatigue BCI applications,\"\nScientific Data, vol. 12, p. 1751, 2025.\nDOI: 10.1038/s41597-025-06032-2", "DatasetDOI": "10.82901/nemar.nm000127", "Version": "1.0.2" }